ADEQ - HOME SAFE DRINKING WATER WATER SYSTEM SEARCH


Water System Detail Information

Water System No.:

AZ0411011

Federal Type:

NP

Water System Name:

ANDERSON BROTHERS WATER COMPANY

Primary Source:

GW

Principal County Served:

PINAL

System Status:

I

Comments:

Activity Date:

2001-09-10



Sample
Number
Analyte
Code
Analyte
Name
Date Sample Point Less
Than
Ind.
Level
Type
Reporting
Level
Concentration MCL Compliance Monitoring Period
95-09044-1 1005 ARSENIC 1995-07-21 EPDS001 .0036  MG/L .01 MG/L
95-09044-1 1010 BARIUM 1995-07-21 EPDS001 < MRL 0.1 MG/L 2 MG/L
95-09044-1 1015 CADMIUM 1995-07-21 EPDS001 < MRL 0.005 MG/L .005 MG/L
95-09044-1 1020 CHROMIUM 1995-07-21 EPDS001 < MRL 0.01 MG/L .1 MG/L
95-09044-1 1025 FLUORIDE 1995-07-21 EPDS001 .35  MG/L 4 MG/L
95-09044-1 1035 MERCURY 1995-07-21 EPDS001 < MRL 0.0002 MG/L .002 MG/L
95-09044-1 1036 NICKEL 1995-07-21 EPDS001 < MRL 0.05 MG/L
95-09044-1 1040 NITRATE 1995-07-21 EPDS001 13  MG/L 10 MG/L
95-09044-1 1045 SELENIUM 1995-07-21 EPDS001 < MRL 0.002 MG/L .05 MG/L
95-09044-1 1052 SODIUM 1995-07-21 EPDS001 < MRL 114 MG/L 3000 MG/L
95-09044-1 1055 SULFATE 1995-07-21 EPDS001 < MRL 212 MG/L 250 MG/L
95-09044-1 1085 THALLIUM, TOTAL 1995-07-21 EPDS001 < MRL 0.005 MG/L .002 MG/L